Resolving InstaStart™ Ignition Performance Issues
If you are having difficulty with your BBQ’s Electronic Ignition a quick visual inspection of the following
will help to identify the cause:
- Check for un-plugged electrode wires or ground wire.
- Check wires for damage including tears or breaks
- Check electrode for cracks in the porcelain insulator
- Replace battery. Ensure battery is installed correctly with
the positive end facing outwards.
- Check battery igniter cap for proper threading
- Check gap between electrode, gas collector box and burner
- Check for damage to Electronic Igniter Box.
- Check to ensure that the Electrode sparks when the igniter button
is pressed.
Replace the battery. Open the Lid.
Press Ignition button and listen for rapid clicks.
Coleman® Even Heat™ Barbecue (Small Spaces)

|
Coleman® Even Heat™ Barbecue (3 Burner)

|
Coleman® Even Heat™ Barbecue (4 Burner)
 |
If a "spark" is not visible at the electrode and burner connection:
- Locate the Electronic Ignition box on the back of the control panel. Check all wire connections.
- Disconnect the corresponding wire and reconnect by pushing the wire in tightly at the connection point.
- If the electrode still does not spark, but a spark and
sound can be heard at the other Ignition points, replace the faulty wire.
Note: All main burner and side burner connection points are the same. |
EVEN HEAT™ Burners Troubleshooting
| Problem |
Identifying the cause |
- Low or out of propane
- Cylinder or the gas supply valve is turned off
- Positive connection has NOT been made between the tank and the regulator. Regulator will not allow fuel in the line.
- The Flow Limiting Device in the regulator has been activated
- Manifold valve assembly is damaged
|
- Burner port holes and/or Venturi tubes are blocked
- Burner is improperly seated on valve gas jet
|
- Blocked Venturi tubes
- Excess cooking salts on burner
|
- Flow Limiting Device has been activated
- High Wind condition – Adjust the placement of Barbecue to shield from wind
- Propane is running low
- Burner improperly seated on valve gas jet
- Heat Distribution plates are not in position
- NATURAL GAS MODELS: Installation issues related to incorrect size supply line installed and /or Water Column supply is not adequate for a Barbecue BTU rating of this grill. Do not use a longer Natural Gas hose than is supplied with your grill.
|
- Barbecue needs to be preheated for 5 to 10 minutes with a closed lid. Outside temperatures will affect the amount of preheat time required.
- Flow limiting device in regulator has been activated and requires resetting
- NATURAL GAS MODELS: Installation issues related to incorrect size supply line installed and /or Water Column supply is not adequate for a Barbecue BTU rating of this grill. Do not use a longer Natural Gas hose than is supplied with your grill.
|
- Proper start up and shut down procedure not followed
- Flow limiting device in regulator has been activated and requires resetting
- Flame Tamers (heat plates) are missing or not in position
- NATURAL GAS MODELS: Installation issues related to incorrect size supply line installed and /or Water Column supply is not adequate for a Barbecue BTU rating of this grill. Do not use a longer Natural Gas hose than is supplied with your grill.
|
- Excessive fat in meat
- Grease drain plugged
- Cooking system including flame tamers and cooking grates have a build up of grease that must be removed
- Lower casting of the Barbecue is clogged with grease
- Cooking on lower temperature setting. Reduce temperatures according to type of foods being cooked.
|